Search results for "Cesium Radioisotopes"

showing 10 items of 12 documents

Effective and environmental half-lives of radiocesium in game from Poland.

2021

For the first time changes in the 137Cs activity in game throughout Poland, including its most contaminated part known as the Opole Anomaly, were analyzed. Due to its long physical half-life, 137Cs continuously demonstrates high activity both in soil and biota. The species of game mammals, along with forest fruit and mushrooms, tend to accumulate this radionuclide, becoming one of the main sources of secondary contamination in people. In this study the 137Cs activity in roe deer, wild boar and red deer muscle tissue samples, within the years of 1986–2019, were studied. The effective and environmental half-lives were determined for each of the mentioned species for four regions including NE …

137CsHealth Toxicology and MutagenesisDeerGameGeneral MedicinePollutionChernobylOpole anomalyEffective half-lifeRadioactivityCesium RadioisotopesRadiation MonitoringEnvironmental ChemistryAnimalsHumansSoil Pollutants RadioactivePolandWaste Management and DisposalHalf-LifeJournal of environmental radioactivity
researchProduct

RADIONUCLIDE CONCENTRATIONS IN AIR PARTICULATE AT PALERMO (ITALY) FOLLOWING FUKUSHIMA ACCIDENT

2012

Following the Fukushima accident, a series of samplings were carried out with a daily frequency to detect the arrival of radioactive contamination in air at Palermo (Italy) and to follow its evolution during the time. Air particulate collection was performed by suction of atmospheric air through cellulose filter paper by means of a high-volume air sampler (∼15 000 m(3) d(-1)). Spectrometric analysis of the filters highlights the presence of (131)I, (134)Cs, (137)Cs and, only for a few samples, traces of (132)Te-(132)I and (136)Cs. Maximum airborne concentrations were 883 μBq m(-3) for (131)I (only particulate), 81 μBq m(-3) for (137)Cs and 70 μBq m(-3) for (134)Cs. From a dose to population…

Atmospheric airTime FactorsSettore ING-IND/20 - Misure E Strumentazione NucleariPopulationAir samplerAir Particulate Fukushima accident airborne concentrationIodine RadioisotopesJapanRadiation MonitoringRadioactive contaminationFukushima Nuclear AccidentRadiology Nuclear Medicine and imagingeducationSicilyRadioisotopeseducation.field_of_studyRadionuclideRadiationRadiological and Ultrasound Technologybusiness.industrySpectrum AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineParticulatesChernobyl Nuclear AccidentAir Pollutants RadioactiveCesium RadioisotopesSpainEnvironmental chemistryNuclear Power PlantsEnvironmental scienceNuclear medicinebusinessUkraine
researchProduct

A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.

2001

The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…

Materials scienceRadiological and Ultrasound Technologybusiness.industryRadioactive sourceRadiotherapy Planning Computer-AssistedMonte Carlo methodBrachytherapyDose levelSievert integralLow-Dose Rate BrachytherapyComputational physicsDistribution (mathematics)Cesium RadioisotopesNeoplasmsVaginaDosimetryHumansRadiology Nuclear Medicine and imagingFemaleDose rateNuclear medicinebusinessRadiometryMonte Carlo MethodAlgorithmsPhysics in medicine and biology
researchProduct

Possible impacts of Hg and PAH contamination on benthic foraminiferal assemblages: An example from the Sicilian coast, central Mediterranean

2007

The Palermo and Augusta urban/industrial areas (Sicily) are examples of contaminated coastal environments with a relatively high influx of unregulated industrial and domestic effluents. Three sediment box-cores were collected offshore of these urban/industrial areas in water depths of 60-150 m during two cruises (summers 2003/2004), dated by (210)Pb and (137)Cs, and analysed for total mercury concentration and total polycyclic aromatic hydrocarbon (PAH) concentration. Benthic foraminiferal assemblages were also examined (in terms of their distribution and morphology) to assess the potential use of benthic foraminifera as bioindicators of pollutant input and environmental change in these Med…

Mediterranean climateGeologic SedimentsmercuryEnvironmental Engineeringbenthic foraminiferachemistry.chemical_elementZooplanktonForaminiferaMediterranean seaMediterranean SeaAnimalsEnvironmental ChemistryDominance (ecology)Polycyclic Aromatic HydrocarbonsSicilyWaste Management and DisposalMercury PAHs 210Pb and 137Cs dating Benthic foraminifera Marine sediments SicilybiologyfungiPaleontologySedimentLead Radioisotopesbiology.organism_classificationPollutionMercury (element)PAHSOceanographychemistryCesium RadioisotopesBenthic zoneBioindicatorWater Pollutants ChemicalPb-210 and Cs-137 datingGeologyEnvironmental MonitoringScience of The Total Environment
researchProduct

Vertical distribution of AhR-activating compounds in sediments contaminated by modernized pulp and paper industry

2013

Increased ethoxyresorufin-O-deethylase (EROD) activity is a sensitive biomarker of exposure to the chemicals which activate the aryl hydrocarbon receptor (AhR) and induce the cytochrome P450 system, such as many polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs). Pulp bleaching was one of the main sources of PCDDs and PCDFs until elemental chlorine free (ECF) and total chlorine free bleaching processes since 1990s have remarkably decreased but not completely eliminate discharges of these chemicals. In addition, historically contaminated sediments may act as a source of these persistent contaminants. In this study, the contam…

PaperGeologic SedimentsEnvironmental EngineeringPolychlorinated Dibenzodioxinsta1172Elemental chlorine freeIndustrial Wastechemistry.chemical_compoundLimit of DetectionCytochrome P-450 CYP1A1AnimalsSoil PollutantsWaste Management and DisposalFinlandWater Science and TechnologyCivil and Structural EngineeringBenzofuransReteneGeographyEcological Modelingfood and beveragesPolychlorinated biphenylSedimentContaminationDibenzofurans PolychlorinatedPulp and paper industryPollutionPolychlorinated BiphenylsKraft processchemistryLiverReceptors Aryl HydrocarbonCesium RadioisotopesEnvironmental chemistryOncorhynchus mykissSewage treatmentPolychlorinated dibenzofuransWater Research
researchProduct

Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type137Cs sources

2001

Basic dosimetric data for the Walstam CDC.K-type low dose rate 137Cs sources in water have been calculated using Monte Carlo techniques. These sources, CDC.K1 -K3 and CDC.K4, are widely used in a range of applicators and moulds for the treatment of intracavitary and superficial cancers. Our purpose is to improve existing data about these sources using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water have been calculated around these sources and are presented as conventional 2D Cartesian look-up tables. Also the AAPM Task Group 43 formalism for dose calculation has been applied. The calculated dose rate constant for the CDC.K1-K3 source is A = 1.106 +/- 0.001…

PhysicsPolynomial regressionModels StatisticalRadiological and Ultrasound TechnologyRadiotherapy Planning Computer-AssistedMonte Carlo methodSievert integrallaw.inventionComputational physicsCesium RadioisotopeslawAnisotropyHumansDosimetryRadiology Nuclear Medicine and imagingCartesian coordinate systemStatistical physicsLow dose rateRadiometryDose rateAnisotropyMonte Carlo MethodAlgorithmsSoftwarePhysics in Medicine and Biology
researchProduct

A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS

2000

The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…

Physicsbusiness.industryAirRadiotherapy Planning Computer-AssistedAttenuationmedicine.medical_treatmentMonte Carlo methodBrachytherapyIsotropyWaterGeneral MedicineSievert integralComputational physicsCesium RadioisotopesLookup tablemedicineHumansDosimetryRadiometryAnisotropyNuclear medicinebusinessMonte Carlo MethodMedical Physics
researchProduct

Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…

2004

The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…

Physicsbusiness.industryPoint sourcemedicine.medical_treatmentAttenuationRadiotherapy Planning Computer-AssistedPhysics::Medical PhysicsMonte Carlo methodBrachytherapyBrachytherapyGeneral MedicineComputational physicsSelectron tubeSuperposition principleCesium RadioisotopesmedicineDosimetryPolar coordinate systemNuclear medicinebusinessRadiometryMonte Carlo MethodSoftwareMedical physics
researchProduct

Monte Carlo dosimetric study of the medium dose rate CSM40 source

2013

Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…

RadiationPhotonPhantoms Imagingbusiness.industryChemistryRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentMonte Carlo methodBrachytherapyWaterRadiotherapy DosageImaging phantomComputational physicsKermaCesium RadioisotopesAbsorbed dosemedicineAnisotropyHumansRadiometryNuclear medicinebusinessRadiation treatment planningMonte Carlo MethodUncertainty analysisApplied Radiation and Isotopes
researchProduct

Modeling of 137Cs migration in soils using an 80-year soil archive: role of fertilizers and agricultural amendments

2008

An 80-year soil archive, the 42-plot experimental design at the INRA in Versailles (France), is used here to study long-term contamination by 137Cs atmospheric deposition and the fate of this radioisotope when associated with various agricultural practices: fallow land, KCl, NH4(NO3), superphosphate fertilizers, horse manure and lime amendments. The pertinence of a simple box model, where radiocaesium is supposed to move downward by convectional mechanisms, is checked using samples from control plots which had been neither amended, nor cultivated since 1928. This simple model presents the advantage of depending on only two parameters: α, a proportional factor allowing the historical atmosph…

business.product_categoryTime FactorsHealth Toxicology and Mutagenesisradioactivitémarquage isotopiquepollution atmosphériqueCesiumSoil science010501 environmental sciences010403 inorganic & nuclear chemistrymodèle01 natural sciencesChernobylPloughSoilddc:550Environmental ChemistrySoil Pollutants RadioactiveRadiocaesiumFertilizersWaste Management and Disposalpratique culturale0105 earth and related environmental sciencesHydrologyamendementRadionuclide[ SDE.BE ] Environmental Sciences/Biodiversity and EcologySoil classificationAgricultureGeneral MedicineCrop rotationManureRADIOACTIVITY;CHERNOBYL;POLLUTION;RADIOCAESIUM;RELATION SOL-ATMOSPHEREPollution0104 chemical sciencesSoil conditionerDeposition (aerosol physics)RadioactivityModels ChemicalCesium RadioisotopesSoil waterEnvironmental science[SDE.BE]Environmental Sciences/Biodiversity and Ecologybusiness
researchProduct